one.two.2 Warning Labels Warning Labels Indicating Be sure to cautiously read through this manual prior to use gadget. The following labels can be a. Tend not to location the gadget with a sloped surface area. If not the out there once the procedure unit may slide, leading to own injuries or the unit works While using the cellular malfunction.

Utmost 4 times tasking for 1 transmitted beam, resulting in exceptional time resolution and higher frame rate.

Get an entire and extended look at with the anatomical structure by way of panoramic imaging coupled with velocity indicator and forward/backward scan skill making scanning a lot easier, smoother and even more controllable.

Never use any cables aside from the cables offered With all the machine by Mindray. 3. Use the cable furnished with This method to attach the printer. Other cables may perhaps bring about electric powered shock. Page fifteen: Mechanical Basic safety

Click on Concur and Move forward to just accept cookies and go straight to the positioning or click More info to find out detailed descriptions of the types of cookies and decide on regardless of whether to just accept particular cookies when on the site.

After you halt the scanning plus the graphic capture, you'll want to electric power from the program and disconnect the process from your AC power provide, then pull out AC power cables. Website page 109: Battery Connecting Board

The chapter materials the tactic to verify major functionality and efficiency of products. This really is only utilized for reference, not preventive execution. Function examining and tests of the part shall be carried out by Mindray support engineers along with the consumer jointly. Web site sixty six: Typical Test

Explore superior diagnostic data by prolonged see of your anatomical structure on all convex probes.

Analyzing clients in nowadays’s demanding surroundings requires progressive technologies that permits clinicians to help make rapid and self-confident diagnoses. The flexibility of the DP-fifty expands your scientific utility whilst helping to make improvements to patient care.

five.two.3 Geometric positioning precision Longitudinal geometric positioning precision  Check Move: Do adjustments as how in tests the maximum depth. Report the distance by 20mm Every single phase within the longitudinal targets line using the measurement caliper; Pick out the worth with the best mistake (to 20mm), determine the accuracy using the system below The measurement caliper must be positioned within the higher fringe of the concentrate on, NOTE:... Webpage 79 Transverse geometric positioning accuracy  Examination Action: Address the scan surface area of your phantom with h2o or pair gel, Carefully Call the probe with the scan surface Modify the depth, producing the transverse targets to get displayed inside the picture. Adjust the main target point to be posited beside the transverse targets (the standard is not apparent) Change parameters like achieve, TGC, generating Every single transverse targets to generally be clearly shown. Webpage eighty 5.5.2.four Blackout Region Exam Phase: Include the scan floor from the phantom with drinking water or pair gel, gently Call the probe with the scan surface area Modify the depth at a lessen value, and set the main target at the nearest location to the scan area. Reduce the value of parameters like AP, Attain till the background sound just can be noticed. Website page eighty one: Computer software Update And Routine maintenance

The DP-fifty Pro can be an ground breaking, significant-effectiveness Ultrasound Technique engineered that may help you obtain the insights you need. The Process’s effective motor and superior-speed processing present exceptional image top quality and an entire info management Option.

Uncover better diagnostic details via extended view of your anatomical framework on all linear probes

Effectiveness Examination five.5.1 Check System Resolution Detection depth Geometric Situation Accuracy Blackout location examination Document the Examination photographs 5.five.2 Take a look at Content The impression utilized Here's just for reference, stick to the impression impact in the true Observe: problem. Specifications: Display: established the distinction and brightness with the medical application price (or perhaps the default status) Procedure atmosphere: darkish place, simulating the medical software environment. Dp50rb login Page seventy six In situation that the transverse resolution testing targets are horizontally displayed, file the small distance of two targets that can be Evidently regarded. Repeat the operation higher than to the transverse resolution tests targets at other depths. As shown in figure down below. Axial resolution ... Webpage seventy seven When utilizing the convex probe, maintain the transverse resolution screening targets to notice: be shown close to the midline. When employing a linear probe with steer functionality, usually do not turn on the steer purpose when carry out the transverse resolution examination. Zoom during the location exactly where the targets Situated if needed. The diameter with the concentrate on point at a specific depth is equivalent into the transverse resolution within the depth. Page seventy eight five.

Mindray respects your privacy. We use cookies for many different uses, like Site performance, bettering your expertise of our website, making integration with social networking and aiding target our marketing.

Return into the process preset interface. The choice status alterations into Uninstalled. The uninstalling perform is distinctive to interior customers.